Hydronic Heating & Cooling Specialists
Home/Products/Boilers/Sime Brava Slim 30 BFR
SIME · REECE AUItalian-built · AS/NZS 4552 certified

Sime Brava Slim 30 BFR

Low-temperature wall-mounted gas boiler — 28.1 kW · heating only

Fonderie SIME's last-generation low-temperature wall-mounted gas boiler — engineered in Italy, certified to Australian standards, distributed by Reece. 28.1 kW heating output, 93.7% efficiency, NOx Class 5. Two variants — BFRi for internal install, BFRe for outdoor (IP X5D weather-rated). AHHAC supplies, installs and services both nationwide.

Nominal output
28.1 kW
Efficiency
93.7%
NOx Class
5 (<70 mg/kWh)
Certification
AS/NZS 4552
Sime Brava Slim 30 BFR wall-mounted gas boiler
BFRi · BFRe variants
Internal & outdoor installations

The short answer

Updated

The Sime Brava Slim 30 BFR is an Italian low-temperature wall-mounted gas boiler for heating only, delivering 28.1 kW nominal output at up to 93.7% efficiency with a NOx Class 5 rating and AS/NZS 4552 certification. It suits homes on mains gas or LPG with radiators, underfloor or skirting heating, and comes as the internal BFRi or the outdoor BFRe. AHHAC supplies, installs and services both variants.

Nominal output
28.1 kW
Max efficiency
93.7%
NOx rating
Class 5
Servicing
Twice yearly

Reviewed by the AHHAC Technical Team — licensed plumbers & hydronic engineers, NSW Lic 262528C.How we write & review

About the Brava Slim 30 BFR

Italian engineering. Australian compliance.

The Brava Slim 30 BFR is Fonderie SIME's last-generation low-temperature wall-mounted gas boiler, designed for HEATING ONLY applications — radiators, hydronic underfloor and skirting heating. Domestic hot water is delivered via a separate hot water cylinder (heated through a hydraulic separator and three-way valve, both supplied by AHHAC as part of the install kit).

Sime's design choices on the Brava Slim are deliberate. An atmospheric burner with a copper heat exchanger gives long-term reliability and easy serviceability. A sealed combustion chamber (sealed from the room it's installed in) means combustion air is drawn from outside via the coaxial flue, eliminating any room-air dependency and meeting modern airtight-build requirements. The microprocessor control board supports OpenTherm modulating remote controls, room thermostat inputs and an external climatic-curve sensor — so flow temperature can vary automatically with outside temperature for 5–10% additional seasonal efficiency.

Two variants serve different install locations. The 30 BFRi (Reece code 8112540) is designed for indoor installation — service cupboards, garages, laundry alcoves. The 30 BFRe (Reece code 8112541) is engineered for outdoor installation with IP X5D weather-rating against atmospheric agents — eave-shelters, side returns, plant decks. Both produce identical heat output and efficiency.

Technical specifications

Models30 BFRi (internal) · 30 BFRe (external)
Reece codes8112540 (BFRi) · 8112541 (BFRe)
Country of installationAustralia
FuelNatural Gas / Universal LPG
Heat input — nominal120 MJ/h
Heat input — minimum60 MJ/h
Heat output — nominal (80/60 °C)28.1 kW
Heat output — minimum (Natural Gas)13.1 kW
Heat output — minimum (LPG)9.2 kW
Max useful efficiency93.7%
Min useful efficiency87.3%
NOx class5 (< 70 mg/kWh)
Heating adjustment range20 – 80 °C
Max operating temperature85 °C
Max operating pressure3.0 bar (300 kPa)
Water content (boiler)3.65 L
Expansion vessel9 L total / 5 L useful
Max system content (default)124 L
Smoke temp at Max/Min flow150 / 100 °C
Number of nozzles13
Nozzle diameter (Natural Gas)1.5 mm
Nozzle diameter (LPG)0.86 mm
Gas consumption (NG, Max/Min)3.17 / 1.59 m³/h
Gas consumption (LPG, Max/Min)1.25 / 0.63 m³/h
Gas supply pressure (NG)11.3 mbar / 1.13 kPa
Gas supply pressure (LPG)27.5 mbar / 2.75 kPa
Power supply230 V / 50 Hz
Absorbed electrical power113 W
Electrical protectionIP X5D
SAI Global licenseSAI-400197
Compliance standardsAS/NZS 4552 · AS/NZS 5601 · AS/NZS 3500 · AS/NZS 3000

Safety & control features

  • Atmospheric burner combined with copper heat exchanger — proven long-life construction.
  • Sealed combustion chamber — combustion air drawn from outside via coaxial flue (BFRe) or natural-draft flue (BFRi).
  • Microprocessor electronic board with OpenTherm-compatible remote control input.
  • External sensor input enables climatic-curve operation — flow temperature varies with outdoor temperature.
  • Anti-freeze function activates automatically below configured threshold (PAR 10 / PAR 11).
  • Anti-blocking pump and diverter valve — auto-cycles every 24 hours if no heat demand.
  • 15-minute chimney-sweep mode for technician combustion checks.
  • Self-diagnostic display with error codes and reset history.
  • 100 °C thermal safety thermostat — over-temperature shutdown.
  • 3-bar pressure relief valve protects expansion vessel and system.
  • Heating water pressure transducer — continuous monitoring.
  • Electronic fan-operation verification — no air pressure switch required.
  • Stand-by, Summer and Winter operating modes (Summer mode N/A on heating-only unit).
Pre-install checks

Five site checks before we install a Sime Brava Slim 30 BFR

The Brava Slim is a compact, forgiving boiler, which is why it's popular for radiator homes on mains gas or LPG. Most problems we see with wall-hung boilers have nothing to do with the boiler itself — they come from skipped site checks. These are the ones we never skip.

  • Gas supply capacity. At full output the boiler draws up to 3.17 m³/h of natural gas. We confirm the meter and the pipe from it can carry that alongside your cooktop and other appliances, and resize the line where needed under AS/NZS 5601.
  • System water volume. The built-in 9 L expansion vessel covers a default system content of 124 L. Larger radiator networks and most underfloor systems hold more water than that, so we add a correctly sized expansion vessel rather than let the relief valve weep every winter.
  • Underfloor temperature. The boiler can be set anywhere from 20 to 80 °C, but a slab should only see 35–45 °C. Where radiators and underfloor share the boiler, a mixing valve and separate circuit protect the floor — see our valves and controls range.
  • Flue and location. Choosing between the BFRi and BFRe comes down to where the flue terminal can legally sit relative to windows, doors and boundaries. We settle the location first, then the variant.
  • Your hot water plan. As a heating-only boiler, it needs a separate hot water source. If the boiler will heat a cylinder, we size it to your household's peak demand and agree how hot-water priority will work on cold winter mornings.

We also recommend fitting the outdoor climatic-curve sensor. It lets the boiler lower its flow temperature on mild days, which keeps rooms steadier and uses less gas across a season, and it makes the twice-yearly service a good moment to fine-tune the curve to how your home actually behaves.

Not sure gas is the right path for your home? Our Immergas vs Sime comparison sets the Brava Slim against an all-electric heat pump on running cost, cooling and hot water.

Written from on-site experience by the AHHAC Technical Team.

Who designs & installs this

Licensed, in-house hydronic engineers — since 1998.

AHHAC's in-house design and service team — licensed plumbers and hydronic engineers (Lic 262528C) who have designed and installed 2,400+ hydronic heating, cooling and hot water systems across Australia since 1998.

We only specify equipment after a heat-loss and system-compatibility check, then supply, install and commission it with our own licensed plumbers to AS/NZS 3500 (plumbing) and AS/NZS 5601 (gas), register the manufacturer warranty and service it for the life of the system.

  • Sized from a heat-loss & compatibility check
  • Authorised Maxa, Viessmann & Immergas supplier
  • Supplied, installed & commissioned in-house
  • Manufacturer warranty registered for you
  • Six showrooms: NSW · ACT · VIC · QLD
  • Spare parts & servicing after install
262528C
NSW plumbing licence
85 164 746 490
ABN (verifiable on ABN Lookup)
2,400+
Hydronic systems installed
Since 1998
Operating in Australia
AS/NZS 3500
Plumbing & drainage standard
AS/NZS 5601
Gas installations standard
Common questions

Sime Brava Slim 30 BFR — FAQ

Who makes the Brava Slim 30 BFR?+
The Brava Slim 30 BFR is designed and manufactured by Fonderie SIME S.p.A., one of Italy's largest hydronic boiler manufacturers. It's distributed in Australia by Reece Plumbing, the country's largest plumbing supply network. AHHAC is an authorised installer and stocks both variants across our six showrooms.
What is the difference between BFRi and BFRe?+
The 30 BFRi (Reece code 8112540) is engineered for internal installation in rooms or service cupboards. The 30 BFRe (Reece code 8112541) is engineered for outdoor installation — rated IP X5D for protection against atmospheric agents (water spray, dust). Both produce the same heat output and efficiency; the BFRe simply has the additional weather-resistant enclosure and coaxial duct arrangement.
What is the heat output?+
Nominal heat output at 80/60 °C flow/return is 28.1 kW. The boiler modulates down to 13.1 kW on natural gas, or 9.2 kW on universal LPG. Nominal heat input is 120 MJ/h (60 MJ/h minimum). This output range covers most residential hydronic systems — typically a 200–280 m² Australian home with radiator or underfloor distribution.
Does the Brava Slim 30 BFR produce hot water?+
No — the Brava Slim 30 BFR is a HEATING-ONLY boiler. For domestic hot water, you'll need a separate hot water cylinder (the boiler can heat the cylinder via a hydraulic separator and three-way valve). 'Summer' mode on the boiler is not applicable for this reason — only Stand-by and Winter modes are active.
What's the efficiency?+
Maximum useful efficiency 93.7% at 80/60 °C operation. Minimum useful efficiency 87.3% at part load. The atmospheric burner is paired with a copper heat exchanger optimised for low-temperature operation. With a climatic-curve external sensor (lowering flow temperature on milder days), seasonal efficiency improves further by 5–10%.
What are the emissions?+
The Brava Slim 30 BFR is rated NOx Class 5 — under 70 mg/kWh of nitrogen oxide emissions, the lowest classification available for gas boilers. CO2 at maximum flow rate is 7.1% (natural gas) / 7.8% (LPG). Gas consumption: 3.17 m³/h max / 1.59 m³/h min on natural gas.
Is the Brava Slim 30 BFR certified for Australian installation?+
Yes — fully certified to Australian standards. AS/NZS 4552 Gas Safety Certification under SAI Global license SAI-400197. Compliant with AS/NZS 5601 (Gas Installations), AS/NZS 3500 (Water Services, Sanitary Plumbing and Drainage) and AS/NZS 3000 (Electrical Installations, Buildings, Structures and Premises). Must be installed by a professionally qualified gas-fitter and electrician.
How often does it need servicing?+
Sime recommend twice-yearly maintenance to maintain warranty validity and ensure safe operation. AHHAC offers an annual service contract that includes both visits — typically a spring service (post-heating season) and an autumn pre-season check. We also handle the 15-minute chimney-sweep function combustion measurement at every service.
What controls and safety features are included?+
Microprocessor electronic control board with OpenTherm-compatible remote control or room thermostat input. Climatic curve operation via external sensor (boiler flow temperature adapts to outdoor temperature). Anti-freeze function (auto-activates below configured threshold), 24-hour anti-blocking pump/diverter cycle, self-diagnostic error codes with display. Safety: 100 °C thermal safety thermostat, 3-bar relief valve, heating water pressure transducer, delivery sensor, electronic fan operation check (no air pressure switch needed).
Where does AHHAC install Sime Brava Slim boilers?+
Across NSW, ACT, VIC and QLD from our Punchbowl (NSW), Laverton North (VIC) and Banyo (QLD) showrooms. Scope includes design, supply, gas-fitter compliance certificate, electrical compliance, commissioning, customer handover and ongoing service contracts.
Last updated Content reviewed by the AHHAC Technical Team (NSW plumbing licence 262528C)Editorial standards