MAXA's integrated wire-controls range — Airmust BMCP A1 on-board thermostats, Airmust P / 3V A1 / 010 A1 wall touch-screens, the CRA wall thermostat and the My House Pro app. Designed to drive MAXA's GRIMPER fan coils, VE inverter fan coils, HCN cassettes and the rest of the MAXA hydronic terminal range from a single integrated platform.

MAXA thermostats are Italian touch-screen wire controls built to run MAXA hydronic terminals: the Airmust BMCP A1 on-board unit, the Airmust P, 3V A1 and 010 A1 wall controllers, the compact CRA thermostat and the My House Pro app. The right model depends on the terminal and whether its fan needs three-speed or 0–10 V modulating control. AHHAC matches, commissions and pairs each thermostat with its terminal before handover.
Reviewed by the AHHAC Technical Team — licensed plumbers & hydronic engineers, NSW Lic 262528C.How we write & review
MAXA's wire-controls and thermostat range is engineered to drive the full MAXA hydronic terminal line — GRIMPER fan coils, VE inverter fan coils, HCN cassettes — from a single integrated control platform. Each thermostat speaks the right native signalling for its assigned terminal type, so there's no mismatch between control output and unit input.
AHHAC selects the right combination for each install at quote stage, factoring in: terminal type (fan coil, cassette, radiator), preferred mounting location (on-board vs wall), control signal needed (three-speed vs 0–10 V modulating), and whether the client wants app-based remote control via My House Pro.
Designed specifically for on-board mounting on the VSL model fan coil machine. The control panel sits directly on the unit — ideal where wall space is limited or where the fan coil is the focal point of the room.
Standard wall-mounted touch thermostat for the MAXA hydronic range. Suits most residential fan coil and cassette applications.
Wall-mounted touch control with three-speed (Low / Med / High) signalling — used for two-pipe fan coils and standard MAXA terminals without inverter drive.
Wall-mounted touch control with 0–10 V output for inverter-driven fan coils. Modulating output gives quieter operation and finer temperature control compared to three-speed switching.
Compact wall-mounted thermostat — the simpler / lower-cost option compared to the Airmust touch-screen range. Pairs with GRIMPER fan coils, VE terminals and HCN cassettes (including MB variants).
Smartphone app for iOS and Android. Connects to the wire-controls range and provides remote setpoint adjustment, scheduling, energy monitoring and multi-zone management.
| Hydronic terminal | CRA | Airmust BMCP A1 | Airmust P | Airmust 3V A1 | Airmust 010 A1 |
|---|---|---|---|---|---|
| GRIMPER MSL | ✓ | ✓ | ✓ | ||
| GRIMPER VSL | ✓ | ✓ | |||
| GRIMPER BSL | ✓ | ✓ | ✓ | ||
| VE: VMI / VMF / OMP / OMI | ✓ | ✓ | ✓ | ||
| VE: VII / VIF / OIP / OII | ✓ | ✓ | ✓ | ||
| VE Vers. MB (VMI/VMF/OMP/OMI) | ✓ | ✓ | ✓ | ✓ | |
| VE Vers. MB (VII/VIF/OIP/OII) | ✓ | ✓ | ✓ | ✓ | |
| HCN | ✓ | ✓ | ✓ | ||
| HCN — Vers. MB | ✓ | ✓ | ✓ | ✓ | |
| HCNP | ✓ | ✓ | ✓ | ||
| HCNP — Vers. MB | ✓ | ✓ | ✓ | ✓ | |
| HCNA | ✓ | ✓ | ✓ | ||
| HCNA — Vers. MB | ✓ | ✓ | ✓ | ✓ |
Source: MAXA wire controls compatibility table.
The thermostat is the part of a hydronic system you touch every day, and it's where we see the most avoidable comfort complaints. Choosing the right MAXA model is only half the job — the zoning plan and where each controller goes matter just as much.
We group rooms by how they're used, not just by floor. Living areas, bedrooms and bathrooms want different temperatures at different times, so each gets its own control. But we don't zone every cupboard: lots of tiny zones calling for heat separately can make a heat pump start and stop more often than it should. In radiator rooms, thermostatic valves often handle the fine-tuning while a wall thermostat sets the schedule.
Signal choice matters too. For inverter fan coils we lean towards the Airmust 010 A1, because a 0–10 V modulating signal lets the fan ease up and down rather than jumping between three speeds — noticeably quieter in bedrooms. Three-speed control on the Airmust 3V A1 remains a sound, simpler choice for standard terminals, and the CRA suits rooms where a basic wall thermostat is all that's needed.
Schedules are where running costs are won. A modest overnight setback and a pre-heat before you wake keeps a slab or radiators comfortable without forcing the heat source to work flat out each morning. We set these up with you in My House Pro at handover and revisit them at the first service.
See our hydronic thermostats overview for other control options, the hydronic fan coils these controllers drive, and the IMAS radiators we often pair with room-by-room control.
Written from on-site experience by the AHHAC Technical Team.
AHHAC's in-house design and service team — licensed plumbers and hydronic engineers (Lic 262528C) who have designed and installed 2,400+ hydronic heating, cooling and hot water systems across Australia since 1998.
We only specify equipment after a heat-loss and system-compatibility check, then supply, install and commission it with our own licensed plumbers to AS/NZS 3500 (plumbing) and AS/NZS 5601 (gas), register the manufacturer warranty and service it for the life of the system.