Hydronic fan coil units for fast heating and chilled-water cooling — wall, bulkhead, cassette and concealed ducted models. AHHAC supplies the MAXA Grimper, HCN, HCNP, HCNA and VE fan coil ranges.

Last updated

The short answer

Updated

A hydronic fan coil unit is an emitter with a quiet fan that blows room air across a water-filled coil, heating it from a heat pump or boiler in winter and cooling and dehumidifying it with 8–14 °C chilled water in summer. It is the fastest-responding hydronic emitter and the one that makes whole-home hydronic cooling practical. AHHAC supplies and installs MAXA Grimper, HCN, HCNP, HCNA and VE fan coil units in wall, bulkhead, cassette and ducted formats.

Primary brand
MAXA (Italy)
Formats
Wall, cassette, ducted
Chilled water range
8–14 °C
Function
Heat, cool, dehumidify

Reviewed by the AHHAC Technical Team — licensed plumbers & hydronic engineers, NSW Lic 262528C.How we write & review

Fan coils are the workhorse emitter for hydronic cooling and fast-response heating. A fan blows room air across a finned hydronic coil — warming it from the boiler/heat pump in winter, or cooling and dehumidifying it from chilled water in summer. Where underfloor is silent and slow, fan coils are fast and powerful, making them ideal for cooling-led climates and rooms that need quick warm-up.

AHHAC supplies the full MAXA hydronic fan coil range: the Grimper Anviro series, the HCN / HCNP / HCNA cassette and bulkhead units, the VE residential and inverter range (VMI, VMF, OMP, OMI / VII, VIF, OIP, OII), and concealed hydronic wall units. Each pairs with the MAXA Airmust and CRA thermostat range for precise control.

Fan coil types we install

Wall-mounted (high or low) — the simplest retrofit, like a split-system head but hydronic. Bulkhead / under-ceiling (HCNA) — concealed above a doorway or in a service zone. Ducted cassette (HCN, HCNP) — fully concealed in the ceiling with grille outlets, the premium invisible option. Concealed floor units — for under-window placement. AHHAC sizes each unit to the room's heating and cooling load and specifies the matching MAXA thermostat.

Key benefits

  • MAXA Grimper, HCN, HCNP, HCNA & VE ranges
  • Heating AND chilled-water cooling from one unit
  • Wall, bulkhead, ducted-cassette and concealed models
  • Built-in dehumidification for humid climates
  • Pairs with MAXA Airmust / CRA thermostats
  • Fast warm-up and powerful cooling output
  • Quiet inverter-fan models available
Install details that matter

Hydronic fan coil units: condensate, noise and sizing for cooling

A fan coil that heats well can still be a poor cooling unit, and in Sydney and Brisbane it is usually the cooling load that sets the size. West-facing glass, top-floor rooms under a hot roof and open-plan living all gain far more heat in summer than they lose in winter, so we size each hydronic fan coil unit to whichever load is larger, which in a humid climate is usually cooling.

Three details that separate a good install from a callback

  • Condensate. Every fan coil running chilled water pulls moisture out of the air, which is the point. That water needs a drain with proper fall, or a condensate pump where gravity will not work. A tray that cannot drain ends up as a stain on the ceiling.
  • Pipe insulation. Chilled-water pipework in a ceiling or wall cavity runs below the dew point of the surrounding air. Without closed-cell, vapour-sealed insulation and taped joints, the pipe sweats and drips long before anyone notices.
  • Fan speed and noise. We select units that deliver the room's design capacity at low-to-medium fan speed, not flat out. That keeps bedrooms quiet at night and leaves headroom for the hottest afternoons.

Format follows the room. A wall unit is the quickest retrofit; a bulkhead unit hides above a doorway or robe; a ducted cassette disappears into the ceiling but needs an access panel for filter cleaning and service. We plan that access before the plasterer arrives, not after.

Fan coils also work well alongside slower emitters. A common layout is underfloor heating in the living areas with fan coils upstairs for cooling and quick warm-up in bedrooms. Each unit runs from its own MAXA wall thermostat, and filters should be cleaned regularly during heavy cooling use.

For the bigger picture, see how hydronic cooling systems work, why hydronic cooling in Sydney relies on dew-point control, and our plain-English hydronic cooling guide.

Written from on-site experience by the AHHAC Technical Team.

Who designs & installs this

Licensed, in-house hydronic engineers — since 1998.

AHHAC's in-house design and service team — licensed plumbers and hydronic engineers (Lic 262528C) who have designed and installed 2,400+ hydronic heating, cooling and hot water systems across Australia since 1998.

We only specify equipment after a heat-loss and system-compatibility check, then supply, install and commission it with our own licensed plumbers to AS/NZS 3500 (plumbing) and AS/NZS 5601 (gas), register the manufacturer warranty and service it for the life of the system.

  • Sized from a heat-loss & compatibility check
  • Authorised Maxa, Viessmann & Immergas supplier
  • Supplied, installed & commissioned in-house
  • Manufacturer warranty registered for you
  • Six showrooms: NSW · ACT · VIC · QLD
  • Spare parts & servicing after install
262528C
NSW plumbing licence
85 164 746 490
ABN (verifiable on ABN Lookup)
2,400+
Hydronic systems installed
Since 1998
Operating in Australia
AS/NZS 3500
Plumbing & drainage standard
AS/NZS 5601
Gas installations standard
Reviews

Trusted by homeowners, builders and strata across Australia

★★★★★
Rated 5-star across NSW · ACT · VIC · QLD
★★★★★

"AHHAC delivered our 22-zone underfloor system on time, on budget and to spec. The crew were tidy, the documentation was thorough, and the commissioning was textbook."

David Chen
Custom Builder · Mosman, NSW
★★★★★

"We've worked with AHHAC for 17 years. They've installed and serviced our hot water plant across three commercial buildings — and they pick up the phone on weekends."

James Holloway
Strata Manager · Melbourne CBD
★★★★★

"Three mobs quoted us; AHHAC's design was the only one based on a proper heat-loss calculation. The system runs beautifully — the others would've been oversized and expensive."

Janelle Smith
Homeowner · Robina, QLD
Last updated Content reviewed by the AHHAC Technical Team (NSW plumbing licence 262528C)Editorial standards