Space Saver Plinth Heater

Discreet under-cabinet hydronic units that kick out warm air on demand — perfect for kitchens and bathrooms where wall space is at a premium and a 100mm kick-space is otherwise wasted.

Last updated

The short answer

Updated

A plinth heater, also called a kickspace heater, is a hydronic fan heater that slides into the 100 mm kick-space under kitchen cabinets or vanities and blows warm air out at floor level. Each unit delivers about 1.0–2.5 kW, enough for a kitchen or bathroom of up to 25–30 m², and runs at 30–40 dB on low fan. AHHAC installs plinth heaters on hydronic systems in Sydney and across NSW, VIC, QLD & ACT.

Unit height
80 mm (100 mm kick)
Output per unit
1.0–2.5 kW
Room size covered
Up to 25–30 m²
Noise on low fan
30–40 dB

Reviewed by the AHHAC Technical Team — licensed plumbers & hydronic engineers, NSW Lic 262528C.How we write & review

Plinth heater installed in a modern kitchen kick-space

Plinth heaters slide into the kick-space beneath your kitchen cabinets or vanity units — that 100mm gap that's normally just dust. They contain a hydronic heat exchanger and a quiet fan, kicking out warm air at floor level when called for.

They're the smartest way to heat a kitchen or bathroom without sacrificing wall space for radiators or floor space for trench heaters.

Where they fit

Standard kitchen kick-space is 100mm tall — most plinth heaters slide in at 80mm. They take a 600mm wide section of plinth (or two for a larger heater).

Output is typically 1.0–2.5 kW, enough to comfortably heat a kitchen or bathroom up to 25–30m². Multiple units can be deployed in larger spaces.

Key benefits

  • Saves all wall and floor space
  • Fits standard 100mm kitchen kick-space
  • Quiet operation — under 35dB on low fan
  • Boost button for fast warm-up
  • Optional remote and timer
  • Removable for service
Coordinate with joinery

Fitting a plinth heater: what your cabinet maker and electrician need to know

Plinth heaters are simple to live with but easy to get wrong in a kitchen renovation, because three trades have to line up: the plumber, the electrician and the cabinet maker. Most of the problems we are called back to sort out are coordination problems, not faulty heaters.

  • Pick the cabinet bay early. Each unit takes a 600 mm section of plinth. It should sit under a fixed base cabinet, not under the dishwasher, oven or fridge, where there is no void and the heat is wasted.
  • Pipe tails before cabinets. Flow and return pipes need to be stubbed up into that bay, with isolation valves, before the carcasses go in. Retrofitting pipe into a finished kitchen means pulling out a cabinet.
  • Power for the fan. Unlike a radiator, a plinth heater has a fan, so your electrician needs to provide a power supply to that bay. It is the item most often missed on kitchen plans.
  • Confirm the kick height. Standard kicks are 100 mm and most units are 80 mm high. Lowered kicks, legs set short or a thick new floor finish can leave too little room, so we measure from the finished floor level, not the drawing.
  • Keep the grille clear. Bins, toe-kick drawers and mats in front of the grille cut output and draw in dust.
  • Service access. Units slide out for cleaning, so the plinth panel in front should clip off rather than be glued in place.

Plinth heaters also work well in laundries and under bathroom vanities, and they pair naturally with other emitters: underfloor or ThermaSkirt skirting heating through the rest of the house, with a plinth heater filling the gap where joinery leaves no free wall or floor. For bathrooms where you want warm tiles rather than warm air, compare a heated bathroom floor. If you are renovating the whole home, our hydronic retrofit guide explains where plinth heaters fit into the wider plan.

Written from on-site experience by the AHHAC Technical Team.

Who designs & installs this

Licensed, in-house hydronic engineers — since 1998.

AHHAC's in-house design and service team — licensed plumbers and hydronic engineers (Lic 262528C) who have designed and installed 2,400+ hydronic heating, cooling and hot water systems across Australia since 1998.

We design space saver plinth heater from a room-by-room heat-loss calculation, install it with our own licensed plumbers to AS/NZS 3500 (plumbing) and AS/NZS 5601 (gas), commission and document it, and service it for the life of the system. Nothing is subcontracted out.

  • Heat-loss calculation before any quote
  • Fixed-fee design back within 24 hours
  • Authorised Maxa, Viessmann & Immergas installer
  • Commissioning report at handover
  • Six showrooms: NSW · ACT · VIC · QLD
  • Ongoing local service & maintenance
262528C
NSW plumbing licence
85 164 746 490
ABN (verifiable on ABN Lookup)
2,400+
Hydronic systems installed
Since 1998
Operating in Australia
AS/NZS 3500
Plumbing & drainage standard
AS/NZS 5601
Gas installations standard
FAQs

Common questions

Will a plinth heater fit my kitchen?

Most kitchen kick-spaces are 100mm tall — standard plinth heaters slide in at 80mm. They take a 600mm wide section of plinth (or two units side-by-side for a larger heater). We'll measure on site.

How much heat does a plinth heater put out?

Typically 1.0–2.5 kW per unit — enough to comfortably heat a kitchen or bathroom up to 25–30m². For larger spaces, we pair multiple units for combined output.

How loud are they?

30–40dB on low fan, 45–55dB on boost. Quieter than a domestic dishwasher or extractor fan. Modern units include a 'silent' mode for evenings.

Reviews

Trusted by homeowners, builders and strata across Australia

★★★★★
Rated 5-star across NSW · ACT · VIC · QLD
★★★★★

"AHHAC delivered our 22-zone underfloor system on time, on budget and to spec. The crew were tidy, the documentation was thorough, and the commissioning was textbook."

David Chen
Custom Builder · Mosman, NSW
★★★★★

"We've worked with AHHAC for 17 years. They've installed and serviced our hot water plant across three commercial buildings — and they pick up the phone on weekends."

James Holloway
Strata Manager · Melbourne CBD
★★★★★

"Three mobs quoted us; AHHAC's design was the only one based on a proper heat-loss calculation. The system runs beautifully — the others would've been oversized and expensive."

Janelle Smith
Homeowner · Robina, QLD
Last updated Content reviewed by the AHHAC Technical Team (NSW plumbing licence 262528C)Editorial standards