HWA2-A — Chiller
Cooling-focused range, suitable for comfort and industrial process cooling. BT version reaches −8 °C fluid temperatures. Available across all 8 sizes.


One machine. Heating, cooling and hot water — guaranteed year-round performance for commercial and industrial buildings. The HWA2 range pairs proven scroll-compressor reliability with R290 natural refrigerant (GWP 3) and water temperatures up to 78 °C. Eight chassis sizes cover everything from a 73 kW boutique hotel to a 192 kW aged-care facility.

A commercial hot water system in Australia can now run on an all-electric heat pump such as the MAXA HWA2, an Italian R290 reversible range that delivers heating, cooling and hot water up to 78 °C from one outdoor unit. Eight sizes cover 60–152 kW of cooling for hotels, aged care, schools, gyms and strata buildings. AHHAC sizes, installs and commissions HWA2 plant across NSW, ACT, VIC and QLD.
Reviewed by the AHHAC Technical Team — licensed plumbers & hydronic engineers, NSW Lic 262528C.How we write & review
The HWA2 is MAXA's industrial reversible chiller and heat pump platform — engineered for commercial and industrial buildings that need heating, cooling and high-temperature hot water from a single piece of plant. By using scroll-compressor reliability and R290 natural refrigerant, it delivers guaranteed year-round performance while future-proofing the building against refrigerant phase-down regulation.
The range splits into two configurations. HWA2-A is the chiller-focused series — suitable for comfort cooling and industrial process applications. The BT (low-temperature) version delivers fluid temperatures as low as −8 °C for process chilling. HWA2-AH is the reversible heat pump series — wide operating range, high maximum water temperature, suitable both for new installations and as a high-efficiency replacement for legacy chillers or boilers without a hydraulic redesign.
Three different frame designs accommodate the eight sizes — single-circuit twin-scroll machines for the 0270–0290 models, twin-circuit four-scroll machines for the 04110–04170 models. Each size can be configured with single or double AC pumps, single inverter pumps, integrated buffer tank, and three acoustic options (Standard, SL, SSL — down to 49 dB(A) at 10 m).
| Model | Heating (AH) kW | Cooling (A) kW | Compressors | Circuits |
|---|---|---|---|---|
| HWA2 0270 | 72.7 | 60.0 | 2 | 1 |
| HWA2 0280 | 78.5 | 67.1 | 2 | 1 |
| HWA2 0290 | 84.4 | 75.7 | 2 | 1 |
| HWA2 04110 | 116 | 98.3 | 4 | 2 |
| HWA2 04120 | 129 | 112 | 4 | 2 |
| HWA2 04140 | 138.6 | 132.4 | 4 | 2 |
| HWA2 04155 | 152.9 | 141.6 | 4 | 2 |
| HWA2 04170 | 167.3 | 152.4 | 4 | 2 |
Each HWA2 size is configurable across pump, tank, fan and acoustic options. AHHAC's commercial engineers spec the exact build per project.
Cooling-focused range, suitable for comfort and industrial process cooling. BT version reaches −8 °C fluid temperatures. Available across all 8 sizes.
Wide operating range and high maximum water temperature. Heats to 78 °C, cools to 7 °C — ideal for new installs and retrofitting existing chillers / boilers.
Single AC, double AC (redundant), or single inverter pump for variable-flow, energy-saving operation. All factory-fitted.
Buffer tank can be paired and integrated at factory — reduces site footprint and simplifies hydraulics. Optional on all sizes.
Standard, SL (super-low), SSL (super-super-low). Down to 49 dB(A) sound pressure at 10 m — suits hotels, hospitals and inner-urban sites.
Optional EC-motor fans for the AH series further reduce part-load power draw and dial-down noise during shoulder-season operation.
Commercial hot water is sized very differently from a house. A hotel, aged-care home or strata building rarely struggles because of total daily use — it struggles at 7 am when everyone showers at once. Before we select an HWA2 size, we work through the same brief on every project.
Our Sydney strata case study shows this process on a building that moved from failing gas boilers to cascaded HWA2 heat pumps. Victorian sites can also see our commercial hot water systems Melbourne page, and our hot water and buffer tanks range covers the storage side of the design.
Written from on-site experience by the AHHAC Technical Team.
AHHAC's in-house design and service team — licensed plumbers and hydronic engineers (Lic 262528C) who have designed and installed 2,400+ hydronic heating, cooling and hot water systems across Australia since 1998.
We only specify equipment after a heat-loss and system-compatibility check, then supply, install and commission it with our own licensed plumbers to AS/NZS 3500 (plumbing) and AS/NZS 5601 (gas), register the manufacturer warranty and service it for the life of the system.